|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
BYV98 Vishay Telefunken Very Fast Soft-Recovery Rectifiers Features D D D D D High reverse voltage Glass passivated Low reverse current Low forward voltage drop Hermetically sealed axial-leaded glass envelope Applications Switched-mode power supplies High-frequency inverter circuits 94 9588 Absolute Maximum Ratings Tj = 25_C Parameter Reverse voltage g =Repetitive peak reverse voltage Test Conditions Type BYV98-50 BYV98-100 BYV98-150 BYV98-200 Symbol VR=VRRM Value 50 100 150 200 70 4 -55...+175 Unit V V V V A A C Peak forward surge current Average forward current Junction and storage temperature range tp=10ms, half-sinewave Tamb = 30C, l = 10 mm IFSM IFAV Tj=Tstg Maximum Thermal Resistance Tj = 25_C Parameter Junction ambient Test Conditions lead length l = 10mm, TL = constant Symbol RthJA Value 25 Unit K/W Electrical Characteristics Tj = 25_C Parameter Forward voltage Reverse current Reverse breakdown voltage Test Conditions IF=5A VR=VRRM VR=VRRM, Tj=150C IR=100mA m Type Symbol VF IR IR V(BR)R V(BR)R V(BR)R V(BR)R trr Min Typ Max 1.1 10 200 Unit V mA mA V V V V ns BYV98-50 BYV98-100 BYV98-150 BYV98-200 60 120 170 220 35 Reverse recovery time IF=0.5A, IR=1A, iR=0.25A Document Number 86046 Rev. 2, 24-Jun-98 www.vishay.de * FaxBack +1-408-970-5600 1 (3) BYV98 Vishay Telefunken Characteristics (Tj = 25_C unless otherwise specified) 120 PR - Reverse Power Dissipation ( mW ) I FAV- Average Forward Current ( A ) VR = VRRM 100 80 60 40 BYV98-50 20 0 25 15784 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 50 75 100 125 150 175 15783 RthJA= BYV98-200 25K/W 70K/W 150K/W BYV98-150 BYV98-100 VR = VR RM half sinewave RthJA=25K/W l=10mm RthJA=70K/W PCB: d=25mm 0 20 40 60 80 100 120 140 160 180 Tj - Junction Temperature ( C ) Tamb - Ambient Temperature ( C ) Figure 1. Max. Reverse Power Dissipation vs. Junction Temperature 1000 VR = VRRM I R - Reverse Current ( mA ) IF - Forward Current ( A ) Figure 3. Max. Average Forward Current vs. Ambient Temperature 100 Tj = 175C 10 Tj = 25C 1 100 10 0.1 1 25 15785 0.01 50 75 100 125 150 175 15782 0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 VF - Forward Voltage ( V ) Tj - Junction Temperature ( C ) Figure 2. Max. Reverse Current vs. Junction Temperature Figure 4. Max. Forward Current vs. Forward Voltage Dimensions in mm Sintered Glass Case SOD 64 Weight max. 1.0 g Cathode Identification 4.3 max. technical drawings according to DIN specifications 1.35 max. 26 min. 4.2 max. 26 min. 94 9587 www.vishay.de * FaxBack +1-408-970-5600 2 (3) Document Number 86046 Rev. 2, 24-Jun-98 BYV98 Vishay Telefunken Ozone Depleting Substances Policy Statement It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances ( ODSs ). The Montreal Protocol ( 1987 ) and its London Amendments ( 1990 ) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2 . Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency ( EPA ) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C ( transitional substances ) respectively. Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 ( 0 ) 7131 67 2831, Fax number: 49 ( 0 ) 7131 67 2423 Document Number 86046 Rev. 2, 24-Jun-98 www.vishay.de * FaxBack +1-408-970-5600 3 (3) |
Price & Availability of BYV98 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |